Cold weather firefighting tips


Name: Lou Angeli


Firefighting in cold weather still requires getting water to handlines and master streams. It's one of the most difficult tasks in winter firefighting. In icy temperatures, leading off from a frozen hydrant or pond may waste valuable minutes. That's why it's important to pre-plan wintertime water supply operations.

In Porter County, Indiana, members of Center Fire & Rescue rely on large diameter supply lines and tanker shuttles to provide adequate water. Planning officers know that it's difficult enough to secure water under ideal situations. But when the weather turns cold, the job becomes much more difficult. So they're preplanned for the worse case scenaio, matching mutual aid companies with their own resources to get the job done. Mutual aid also plays a vital role during "working" assignments, especially when one factors in firefighter rehab.

Important tips
Fighting fires in cold weather isn't only uncomfortable for front line personnel, it's damaging to equipment as well. Here are some tips from departments around the country, that may prove useful during cold weather incidents in your area:

  • Avoid coming up DRY, by initiating a hydrant "Pump-Out" plan
  • Apparatus maintenance is crucial! Make sure that tire chains or other traction devices are available for all first-in units
  • Develop a "contingency plan" with the authority or agency responsible for road maintenance and service 
  • Develop SOPs regarding "dry-pump" vs. "wet-pump" operations. Things to consider are response time, pump design and normal ambient temperature in the station
  • Carry a supply of salt, sand or oil-dry to enhance footing and reduce the possibility of falls
  • During heavy snowfalls, apparatus may be forced to operate "away" from the fire building
  • Extra lengths of attack line should be added to preconnects to compensate for the additional stretch
  • Following knockdown, when handlines are in standby, partially opened control valves will allow water to flow and prevent freezing.
  • Make sure that all waterways for monitors or deck pipes are dry, to avoid any freezing or clogging effects resulting from ice or slush
  • Follow the manufacturer's recommendations regarding the cold weather use of SCBA. Don't allow water to seep into regulators or emmission valves.

And finally, ensure that extra turnout gear is available, especially gloves. It's recommended that personnel wear layered clothing, rather than bulky articles.

Ours is a unique profession. As firefighters and EMTs, we're called upon to perform a number of important tasks, in a wide range of weather conditions. So whether we're working in desert heat — or arctic cold — our mission is always the same: to save the folks inside, and perhaps save their home.

Resources
(1) NOAA
(2) US Weather Service
(3) Battalion Chief Edward Hojnicki

Lou Angeli has been involved in filmmaking, television production and firefighting most of his life. On Sept. 11, 2002, while a member of the Kennett Fire Department in suburban Philadelphia, Angeli left fire-rescue as an active member. His focus now is making films that deal with emergency response and disasters, training first responders and serving as a firefighter advocate. Angeli now resides in Wilmington, Delaware.



Print Talk Back Register BookmarkRSSWhat's This Submit

Member Comments: Submit Your Comment
FireRescue1 encourages its members to comment on this article in the comments section below. You must be a registered member of FireRescue1 to post a comment. The comments below are member-generated and do not necessarily reflect the opinions of FireRescue1 or its staff.

Most Commented Articles
 1.  The Things I Carried
 2.  Federal high-visibility vest rule takes effect
 3.  Interior Use of Positive Pressure – Part 1
 4.  Vacant buildings boarded up after vagrants blamed in Va. fire
 5.  What's Going On Out There?
 6.  Fla. city settles suit with volunteer firefighters
 7.  Safety of Ohio firefighters put to test by area company
 8.  Ohio fire chief under investigation over alleged shoving
 9.  Mo. chief says FD conflict still about race
 10.  Heads bow in memory of 9/11 victims




Safety Columnist
Jeffrey O. Stull
Sponsored by Globe
PPE Update
The Next Generation of SCBA
All Articles

Safety Articles
Federal high-visibility vest rule takes effect - 11/24/2008 2 Philadelphia firefighters hurt as roof collapses - 11/21/2008 Mass. firefighter hurt in fall through floor - 11/19/2008 Foreclosures challenge fire departments - 11/19/2008 Communicating Safety - 11/18/2008
More articles
Safety Tips
Enforcing the rules Care tips for thermal burns patients Safety tips during overhaul Lead by example Tackling vehicle fires
More tips
Videos
Firefighter Safety: Not Just About You East Joliet, Ill. Fire Rescue - House Fire Houston Texas firefighter mayday Sprinkler Demonstration CSB: Blast Wave in Danvers
More Videos